NVIDIA MFP7E20-N015 1:2 Splitter Cable | 800G to 2x400G MPO-12/APC OM4, 15m

Detail produk:

Nama merek: Mellanox
Nomor model: MFP7E20-N015
Dokumen: MFP7E20-Nxxx.pdf

Syarat-syarat pembayaran & pengiriman:

Kuantitas min Order: 1 buah
Harga: Negotiate
Kemasan rincian: Kotak luar
Waktu pengiriman: Berdasarkan persediaan
Syarat-syarat pembayaran: T/T
Menyediakan kemampuan: Pasokan dengan proyek/batch
Harga terbaik Kontak

Informasi Detail

Model TIDAK.: MFP7E20-N015 Bentuk Bahan: Kawat Bulat
Kekuatan tarik yang diizinkan: 1000n <10000n Sertifikasi: RoHS, CE, ISO9001, VDE, CCC
Bahan Sarung: PVC Panjang: 15m
Kecepatan Data: 400GB/s Asal: India / Israel / Cina

Deskripsi Produk

NVIDIA MFP7E20-N015 Multimode 1:2 Splitter Cable
800G Twin-Port OSFP to 2x 400G OSFP/QSFP112 – Type B Crossover, 15m, OM4

The NVIDIA MFP7E20-N015 is a high-performance passive optical splitter cable designed to link one twin-port OSFP 800Gb/s transceiver to two independent 400Gb/s OSFP or QSFP112 transceivers. Engineered with MPO-12/APC connectors, 8 active fibers (50/125μm OM4), and Type B crossover topology, it ensures seamless signal integrity for InfiniBand NDR, Ethernet, and NVLink fabrics. Ideal for spine-leaf architectures in AI clusters, data centers, and high-performance storage.

Product Overview

The NVIDIA MFP7E20-Nxxx series provides a unique 4‑channel‑to‑two‑2‑channel splitting function within a single MPO-12/APC to dual MPO-12/APC assembly. The MFP7E20-N015 offers 15 meters of reach using low-loss OM4 multimode fiber with aqua LSZH jacket. The angled physical contact (APC) polish (8‑degree) eliminates back reflections and maintains superior optical return loss ≥35 dB. This breakout cable enables one 800G port (twin OSFP) to fan out into two independent 200G/400G links, maximizing port density and reducing switch‑to‑adapter cabling complexity. Each cable is rigorously factory‑tested, Telcordia GR‑1435 compliant, and supports push‑pull latches for easy deployment.

Key Features

1:2 Breakout Topology
One MPO-12/APC (8 fibers active) splits into two separate MPO-12/APC connectors each carrying 4 fibers (2x200G or 400G per branch).
High Density & Protocol Agnostic
Supports InfiniBand NDR, 800G/400G Ethernet, and NVLink; fully passive and transparent.
Angled Polish Connectors
APC finish reduces back reflections (return loss ≥35 dB) for superior signal quality.
Type B Crossover Wiring
Crossed fiber mapping ensures correct TX/RX alignment between transceivers without external polarity adjustments.
LSZH / OFNR Jacket
Low smoke zero halogen jacket rated for plenum/riser spaces (LSZH/OFNR), aqua color indicating OM3/OM4 multimode.
Rugged & Easy Installation
Push-pull latching, dust caps pre-installed, 3.0 mm round cable diameter, 30 mm min bending radius.

Technology & Construction

Built around 50/125μm multimode fiber (OM3 for ≤30m models, OM4 for >30m; MFP7E20-N015 utilizes OM4 for extended 15m performance with low insertion loss). The MPO-12/APC female connectors incorporate alignment holes that match transceiver pins, guaranteeing precise optical alignment. The “crossover” Type‑B interconnection ensures that lane 1 at the 4‑channel end (twin‑port OSFP side) maps to lane 12 at the first branch and lane 2 to lane 11 at the second branch, effectively enabling full-duplex communication. NVIDIA’s stringent insertion loss budget (≤0.35 dB + 0.0004 x L) ensures link reliability across temperature and humidity variations (-40°C to 85°C storage, 0-70°C operating).

Typical Deployments

  • Connecting NVIDIA twin‑port OSFP 800G transceivers (e.g., MMA4Z00‑NS) in top‑of‑rack switches to ConnectX‑7 or BlueField‑3 DPU adapters using 400G OSFP/QSFP112 modules.
  • High‑density server clustering where two servers share one switch port via 1:2 splitter configuration (each branch serves a separate compute node).
  • AI/ML clusters requiring 200G per branch from a single 800G port, reducing cable bulk and optimizing airflow.
  • Spine‑Leaf networks in data centers using multimode fiber for short‑reach, cost‑effective high‑speed interconnects up to 50 meters (with up to 2 patch panels).

Compatibility & Ecosystem

The MFP7E20-N015 is designed for seamless integration with NVIDIA end-to-end networking solutions. It mates with all standard MPO‑12/APC optical interfaces (female connectors) and is compatible with:

  • Twin‑port OSFP transceivers: MMA4Z00‑NS (800G DR8), MMA4Z00‑NS400 (400G DR4+)
  • Single‑port OSFP / QSFP112 transceivers: MMA1Z00‑NS400, QSFP112 400G DR4 modules
  • Network adapters: NVIDIA ConnectX‑7, ConnectX‑6 (with appropriate cage/adapter), BlueField‑3 DPUs
  • Switches: NVIDIA Quantum-2, Spectrum-4 based platforms with OSFP cages.
 Important: Both ports on twin‑port OSFP transceivers must use the same fiber type (both splitter cables or both straight cables). Mixing splitter and straight cables on the same transceiver is not supported. Also, MPO-12/APC connectors are not compatible with blue MPO-12/UPC connectors due to different ferrule polish angles.

Technical Specifications

Parameter Specification (MFP7E20-N015)
Product Type Passive 1:2 Optical Splitter Cable
Connector Type MPO-12/APC (female) to 2x MPO-12/APC (female)
Fiber Type 50/125μm Multimode OM4 (for lengths >30m; 15m uses OM4)
Number of Active Fibers 8 fibers (4 transmit / 4 receive per branch mapping)
Cable Length 15 meters (tolerance: +2% x L / -0)
Insertion Loss (max) ≤0.35 dB + 0.0004 x L (L=15m → ≤0.356 dB per connector end face)
Return Loss ≥35 dB (APC polish)
Jacket Material & Color LSZH / OFNR, Aqua
Cable Diameter 3.0 ± 0.2 mm
Minimum Bend Radius 30 mm (static)
Operating Temperature 0°C to 70°C
Storage Temperature -40°C to 85°C
Topology / Polarity Type B (crossover) per MPO standards
Regulatory Compliance RoHS, IEC 61754-7, Telcordia GR-1435, Class 1 Laser Product (IEC 60825-1/2)

Selection Guide – MFP7E20-Nxxx Family

Ordering Part Number Description Length Fiber Type
MFP7E20-N003 NVIDIA passive fiber cable, MMF, MPO12 APC to 2xMPO12 APC 3m OM3
MFP7E20-N005 NVIDIA passive fiber cable, MMF, MPO12 APC to 2xMPO12 APC 5m OM3
MFP7E20-N007 NVIDIA passive fiber cable, MMF, MPO12 APC to 2xMPO12 APC 7m OM3
MFP7E20-N010 NVIDIA passive fiber cable, MMF, MPO12 APC to 2xMPO12 APC 10m OM3
MFP7E20-N015 NVIDIA passive fiber cable, MMF, MPO12 APC to 2xMPO12 APC 15m OM4
MFP7E20-N020 NVIDIA passive fiber cable, MMF, MPO12 APC to 2xMPO12 APC 20m OM4
MFP7E20-N030 NVIDIA passive fiber cable, MMF, MPO12 APC to 2xMPO12 APC 30m OM4
MFP7E20-N050 NVIDIA passive fiber cable, MMF, MPO12 APC to 2xMPO12 APC 50m OM4

Advantages & Reliability

Factory Verified Performance
100% optically tested for insertion loss, return loss, and polarity.
Future-Proof Scalability
Supports 200G per fiber branch, enabling 400G/800G migration without re-cabling.
Low Latency & Passive Design
No active electronics – ideal for latency‑sensitive HPC and AI workloads.
Reduced Cable Spaghetti
Combines two branches into one MPO, simplifying cable management.

Service & Support

Hong Kong Starsurge Group provides full lifecycle support for NVIDIA original optical products including technical pre‑sales consultation, compatibility validation, and logistics worldwide. Every MFP7E20-N015 cable is sourced directly from authorized NVIDIA supply chain. Our engineering team assists with network topology design, transceiver matching, and on-site installation guidance. For RMA or technical queries, reach us at networking-support@starsurge.com or contact your dedicated account manager.

Frequently Asked Questions

Can I use MFP7E20-N015 with QSFP56 or older 100G transceivers?
No. The splitter is designed for MPO‑12/APC interfaces used in 200G/400G/800G PAM4 optics. For 100G NRZ (blue MPO/UPC), compatibility is not guaranteed due to polish and loss budget differences.
What is the maximum reach with patch panels?
NVIDIA specifies up to 50m total link length assuming up to two optical patch panels (4 connector junctions). For 15m cable, insertion loss remains well within transceiver limits.
Are both branches required to be plugged in simultaneously?
Both branches can operate independently; unused branch should be capped with a dust cap to avoid contamination. The splitter cable is passive and does not require both ends active.
Can this cable be used in NVLink Switch Systems?
Yes. NVLink topologies using OSFP ports support this 1:2 splitter to connect GPUs or DPUs with 400G links. Verify transceiver compatibility with your NVIDIA account team.

Handling Precautions

  • Do not remove dust caps until the moment of installation. Contaminated connectors must be cleaned using optical connector cleaners (never use alcohol wipes on end face without proper tools).
  • Avoid bending the cable beyond a 30 mm radius; sharp kinks can permanently damage fibers.
  • Keep cables away from liquids and high‑humidity environments beyond specifications.
  • ESD precautions are required when handling transceivers, but the fiber cable itself is non‑conductive.
  • Never force the MPO connector; align the key and gently push until latching occurs.

About Hong Kong Starsurge Group

Hong Kong Starsurge Group Co., Limited is a technology-driven provider of network hardware, IT services, and system integration solutions. Founded in 2008, the company serves customers worldwide with products including network switches, NICs, wireless access points, controllers, cables, and related networking equipment. Backed by an experienced sales and technical team, Starsurge supports industries such as government, healthcare, manufacturing, education, finance, and enterprise. The company also offers IoT solutions, network management systems, custom software development, multilingual support, and global delivery. With a customer-first approach, Starsurge focuses on reliable quality, responsive service, and tailored solutions that help clients build efficient, scalable, and dependable network infrastructure.

Partner with us for genuine NVIDIA MFP7E20 series cables, fast shipping, and expert engineering support.

Key Facts at a Glance

  • 1:2 fanout: 800G → 400G + 400GType B Polarity: Crossed wiring ensures TX/RX alignment
  • OM4 grade: Optimized for 400G-800G PAM4 signals
  • Global certification: FCC Class A, CE, RCM, ICES, VCCI, CB, cTUVus

Compatibility Matrix (Key Transceivers)

Transceiver Model Form Factor Data Rate Compatible with MFP7E20-N015
MMA4Z00-NS Twin-port OSFP 800G DR8 Yes (uses both splitter cables)
MMA4Z00-NS400 OSFP 400G DR4 Yes – branch side
MMA1Z00-NS400 QSFP112 400G DR4 Yes – branch side
Generic 400G DR4/FR4 (MPO-12/APC) OSFP/QSFP112 400G Yes, if APC interface and loss budget met
100G SR4 (MPO-12/UPC) QSFP28 100G NRZ No (polish mismatch)

Buyer Checklist – MFP7E20-N015

  • Confirm transceivers on both ends require MPO‑12/APC female interface (key up).
  • Verify cable length (15m) fits your rack-to-rack or within row distance.
  • Check switch ports: twin‑port OSFP ports must be paired with two splitter cables for full 800G utilization.
  • Plan for dust caps and cleaning kits – mandatory for maintaining low insertion loss.
  • Ensure operating environment temperature range 0-70°C, no excessive bends.

Related Products

  • NVIDIA MMA4Z00-NS – 800G twin‑port OSFP DR8 transceiver
  • NVIDIA MMA1Z00-NS400 – 400G QSFP112 DR4 transceiver
  • NVIDIA MFP7E20-N050 – 50m OM4 splitter cable for extended reach
  • MPO-12 APC to MPO-12 APC Type B trunk cables (straight, non-splitter)
  • Optical cleaning pens & cassette cleaners for MPO connectors